AIt opens the circuit by melting when current exceeds a safe value. ✓ Correct answer
BIt increases the resistance of the circuit.
CIt stores excess current.
DIt reduces the supply voltage.
✓ Correct answer: It opens the circuit by melting when current exceeds a safe value.
Full explanation
A fuse contains a thin wire that melts when the current gets too high, breaking the circuit. It opens the circuit by melting when current exceeds a safe value.
AThe planned disconnection of supply when demand exceeds generation. ✓ Correct answer
BThe increase of generation to meet demand.
CThe storage of excess power.
DThe repair of transmission lines.
✓ Correct answer: The planned disconnection of supply when demand exceeds generation.
Full explanation
When demand is higher than available generation, parts of the network are switched off in rotation. Load shedding is the planned disconnection of supply when demand exceeds generation.
How is the power factor of an inductive load usually improved?
ABy adding a resistor in series.
BBy connecting capacitors in parallel. ✓ Correct answer
CBy reducing the supply voltage.
DBy adding an inductor in series.
✓ Correct answer: By connecting capacitors in parallel.
Full explanation
Capacitors supply the reactive power that inductive loads need, so the supply sees less reactive current. The power factor is improved by connecting capacitors in parallel.
What type of insulator is used to support high-voltage transmission line conductors?
APin insulator only.
BSuspension (disc) insulator. ✓ Correct answer
CShackle insulator.
DStay insulator.
✓ Correct answer: Suspension (disc) insulator.
Full explanation
For high voltages, conductors hang from strings of disc insulators that can be extended for higher voltage. The type used is the suspension (disc) insulator.
Electrical EngineeringPower SystemsID: PWS-001
What is the diversity factor of a power system?
AThe sum of the individual maximum demands divided by the maximum demand of the whole system ✓ Correct answer
BThe average load divided by the maximum demand
CThe maximum demand divided by the connected load
DThe average load divided by the rated plant capacity
✓ Correct answer: The sum of the individual maximum demands divided by the maximum demand of the whole system
Full explanation
The diversity factor is the sum of the individual maximum demands of the consumers divided by the maximum demand of the whole system. Because consumers do not all reach their peak at the same hour, it is always greater than 1. The correct answer is The sum of the individual maximum demands divided by the maximum demand of the whole system.
Electrical EngineeringPower SystemsID: PWS-002
What is the demand factor of a power system?
AThe average load divided by the maximum demand
BThe maximum demand divided by the connected load ✓ Correct answer
CThe sum of the individual maximum demands divided by the system maximum demand
DThe energy consumed divided by the maximum demand
✓ Correct answer: The maximum demand divided by the connected load
Full explanation
The demand factor is the maximum demand divided by the connected load. It says how much of everything connected was ever switched on at once, so it is always less than 1.
Electrical EngineeringPower SystemsID: PWS-003
What is the plant capacity factor of a power station?
AThe maximum demand divided by the connected load
BThe average load divided by the rated capacity of the plant ✓ Correct answer
CThe sum of the individual maximum demands divided by the system maximum demand
DThe peak load divided by the base load
✓ Correct answer: The average load divided by the rated capacity of the plant
Full explanation
The plant capacity factor is the average load divided by the rated capacity of the plant. It says how much of what the plant could have produced it actually produced over the period.
Electrical EngineeringPower SystemsID: PWS-004
What are the two parts of a two-part tariff for electricity?
AA fixed charge and a running charge ✓ Correct answer
BA peak charge and an off-peak charge
CA meter charge and a fuel charge
DA demand charge and a tax charge
✓ Correct answer: A fixed charge and a running charge
Full explanation
A two-part tariff has a fixed charge, based on the consumer's maximum demand, and a running charge, based on the units of energy used. The fixed charge pays for the plant that must exist, and the running charge pays for the fuel burned. The correct answer is A fixed charge and a running charge.
Electrical EngineeringPower SystemsID: PWS-005
What is meant by the base load of a power system?
AThe highest demand reached during the day
BThe steady minimum demand that must be supplied all day ✓ Correct answer
CThe load that is switched off during peak hours
DThe total connected load of all consumers
✓ Correct answer: The steady minimum demand that must be supplied all day
Full explanation
The base load is the steady minimum demand that must be supplied continuously, day and night. The peak load is the short, high demand on top of it, supplied by peak-load plants started only for the peak. The correct answer is The steady minimum demand that must be supplied all day.
Electrical EngineeringPower SystemsID: PWS-006
What does the area under a load curve represent?
AThe maximum demand of the system
BThe load factor of the system
CThe energy consumed over the period ✓ Correct answer
DThe diversity factor of the system
✓ Correct answer: The energy consumed over the period
Full explanation
A load curve plots load against time, so the area under it is load multiplied by time, which is the energy consumed over the period.
Electrical EngineeringPower SystemsID: PWS-007
A power station has an average load of 60 MW and a maximum demand of 100 MW. What is its load factor?
A0.40
B0.60 ✓ Correct answer
C1.67
D0.06
✓ Correct answer: 0.60
Full explanation
Load factor is the average load divided by the maximum demand: 60 / 100 = 0.60. A high load factor means the plant was used steadily.
Electrical EngineeringPower SystemsID: PWS-008
The individual maximum demands of the consumers on a system add up to 600 kW, but the maximum demand of the whole system is 500 kW. What is the diversity factor?
A0.83
B1.20 ✓ Correct answer
C1.00
D0.20
✓ Correct answer: 1.20
Full explanation
Diversity factor is the sum of the individual maximum demands divided by the maximum demand of the system: 600 / 500 = 1.20. It is greater than 1 because the consumers do not all peak at the same hour.
Electrical EngineeringPower SystemsID: PWS-009
A hydroelectric station has a water flow rate of 10 cubic metres per second, an effective head of 50 metres and an overall efficiency of 80%. What is the approximate power output? (Take g = 9.81 m/s² and water density = 1000 kg/m³.)
A3.92 MW ✓ Correct answer
B4.90 MW
C39.2 MW
D0.39 MW
✓ Correct answer: 3.92 MW
Full explanation
Power P = ρgQHη = 1000 × 9.81 × 10 × 50 × 0.80 = 3,924,000 W, which is about 3.92 MW.
Electrical EngineeringPower SystemsID: PWS-010
Which fault is the most severe fault in a power system?
ASingle line-to-ground fault
BLine-to-line fault
CDouble line-to-ground fault
DThree-phase fault ✓ Correct answer
✓ Correct answer: Three-phase fault
Full explanation
The three-phase fault is the most severe fault, because all three phases are shorted together and the fault current is the largest. The single line-to-ground fault is the most frequent, but it is less severe.
Electrical EngineeringPower SystemsID: PWS-011
What does an overcurrent relay do in a power system?
AIt measures the voltage at the busbar
BIt operates when the current exceeds a preset value ✓ Correct answer
CIt compares the currents at the two ends of a line
DIt detects the direction of the fault current
✓ Correct answer: It operates when the current exceeds a preset value
Full explanation
An overcurrent relay operates when the current in the circuit exceeds a preset value, for example during an overload or a short circuit, and trips the circuit breaker. The correct answer is It operates when the current exceeds a preset value.