A 3-phase, 4-wire system is used mainly to supply which kind of load?
AUnbalanced loads with a neutral return ✓ Correct answer
BDC loads
CBalanced 3-phase loads only
DSingle-phase loads only
✓ Correct answer: Unbalanced loads with a neutral return
Full explanation
The correct answer is Unbalanced loads with a neutral return. A 3-phase, 4-wire system provides a neutral wire, so unbalanced loads can return current through the neutral.
What is the primary function of a busbar in a substation?
ATo step up the voltage
BTo conduct and distribute power to outgoing feeders ✓ Correct answer
CTo measure the line current
DTo store electrical energy
✓ Correct answer: To conduct and distribute power to outgoing feeders
Full explanation
The correct answer is To conduct and distribute power to outgoing feeders. A busbar is a common conductor that collects power from incoming circuits and distributes it to outgoing feeders.
The Ferranti effect in a long transmission line causes the receiving-end voltage to be what under no-load conditions?
AHigher than the sending-end voltage ✓ Correct answer
BEqual to the sending-end voltage
CLower than the sending-end voltage
DZero
✓ Correct answer: Higher than the sending-end voltage
Full explanation
The correct answer is Higher than the sending-end voltage. Under no-load conditions the line capacitance charges the line, so the Ferranti effect makes the receiving-end voltage higher than the sending-end voltage.
Which of the following is used to improve the power factor of an industrial load?
ASynchronous condenser ✓ Correct answer
BInduction motor
CResistive heater
DDC generator
✓ Correct answer: Synchronous condenser
Full explanation
The correct answer is Synchronous condenser. A synchronous condenser is an over-excited synchronous motor that supplies leading reactive power and improves the power factor.
In load flow studies, the slack bus is used to account for which quantity?
AReactive power only
BLoad demand only
CTransformer tap settings
DTransmission losses ✓ Correct answer
✓ Correct answer: Transmission losses
Full explanation
The correct answer is Transmission losses. The slack bus absorbs the mismatch between generation and load, so it accounts for the transmission losses in the load flow solution.
The corona loss in a transmission line increases with which of the following?
AIncrease in air density
BDecrease in system voltage
CDecrease in conductor diameter ✓ Correct answer
DIncrease in conductor spacing
✓ Correct answer: Decrease in conductor diameter
Full explanation
The correct answer is Decrease in conductor diameter. Corona loss rises when the conductor diameter decreases, because the smaller surface raises the voltage gradient around the conductor.
What distinction does Tarbela Dam hold in the world?
AThe largest earth-filled dam in the world. ✓ Correct answer
BThe tallest concrete dam in the world.
CThe longest dam in the world.
DThe deepest dam in the world.
✓ Correct answer: The largest earth-filled dam in the world.
Full explanation
Tarbela Dam, built on the Indus River, is the largest earth-filled dam in the world by volume. So the distinction is that it is the largest earth-filled dam in the world.
Why is a step-up transformer used at a generating station?
ATo reduce transmission losses. ✓ Correct answer
BTo increase the current.
CTo reduce the frequency.
DTo store energy.
✓ Correct answer: To reduce transmission losses.
Full explanation
Raising the voltage reduces the current for the same power, and losses depend on current squared. So a step-up transformer is used to reduce transmission losses.
BCurrent concentrates near the surface of the conductor. ✓ Correct answer
CCurrent flows only through the centre.
DCurrent stops flowing at high frequency.
✓ Correct answer: Current concentrates near the surface of the conductor.
Full explanation
Alternating current tends to flow in the outer layers of a conductor because of the changing magnetic field inside it. The current concentrates near the surface of the conductor.
What is corona in a high-voltage transmission line?
AThe heating of the conductor.
BThe ionisation of air around the conductor. ✓ Correct answer
CThe sagging of the conductor.
DThe vibration of the conductor.
✓ Correct answer: The ionisation of air around the conductor.
Full explanation
When the electric field at the conductor surface is strong enough, the surrounding air breaks down and glows. Corona is the ionisation of air around the conductor.
BTo interrupt fault current and isolate a faulty section. ✓ Correct answer
CTo step up voltage.
DTo measure power.
✓ Correct answer: To interrupt fault current and isolate a faulty section.
Full explanation
A circuit breaker opens its contacts to stop current flow when a fault occurs. Its function is to interrupt fault current and isolate a faulty section.