AElectrical resistance at the joint ✓ Correct answer
BAn electric arc
CA gas flame
DFriction only
✓ Correct answer: Electrical resistance at the joint
Full explanation
Spot welding is a resistance welding process: a heavy current is passed through the two sheets squeezed between copper electrodes, and the electrical resistance at the joint (I-squared-R heating) melts a small nugget of metal. No filler metal is used and no arc is struck - unlike gas welding, where filler metal is added.
Quenching media in order of cooling rate, fastest to slowest, are brine, water, oil, and air. Brine is fastest because the salt breaks up the vapour blanket that insulates the hot steel; water is next, oil is much slower, and air is slowest and is used only for air-hardening steels. Faster is not better in itself - too fast a quench cracks the part.
In the iron-carbon diagram, the eutectoid reaction takes place at:
A0.8% carbon and 727 C ✓ Correct answer
B4.3% carbon and 1147 C
C2.14% carbon and 1147 C
D6.67% carbon and 727 C
✓ Correct answer: 0.8% carbon and 727 C
Full explanation
At the eutectoid point - 0.8% carbon and 727 C - austenite transforms on cooling into pearlite, a layered mixture of ferrite and cementite. The eutectic point is different: 4.3% carbon at 1147 C, where liquid becomes ledeburite. The 2.14% figure is the maximum carbon austenite can dissolve, and 6.67% is the carbon content of cementite (Fe3C).
Steel is classified as low-carbon steel when its carbon content is:
ABelow about 0.3% ✓ Correct answer
B0.6% to 1.0%
C1.0% to 2.0%
DAbove 2.14%
✓ Correct answer: Below about 0.3%
Full explanation
By carbon content, steels are classed as low-carbon (below about 0.3%), medium-carbon (about 0.3% to 0.6%) and high-carbon (about 0.6% to 1.5%). Above about 2.14% carbon the alloy is cast iron, not steel. Mild steel, at 0.15% to 0.30% carbon, is a low-carbon steel.
What is the least count of a standard metric vernier caliper?
A0.02 mm ✓ Correct answer
B0.01 mm
C0.1 mm
D0.5 mm
✓ Correct answer: 0.02 mm
Full explanation
The least count is one main-scale division minus one vernier-scale division: 1 mm - 0.98 mm = 0.02 mm (50 vernier divisions cover 49 main-scale divisions). A vernier caliper therefore reads to 0.02 mm, while a micrometer reads finer, to 0.01 mm.
What is the least count of a standard metric outside micrometer?
A0.01 mm ✓ Correct answer
B0.02 mm
C0.1 mm
D0.001 mm
✓ Correct answer: 0.01 mm
Full explanation
The least count is the screw pitch divided by the number of thimble divisions: 0.5 mm pitch / 50 divisions = 0.01 mm. The micrometer is therefore twice as fine as a standard vernier caliper (0.02 mm) and is used where that extra precision is needed.
Tolerance on a dimension is the difference between:
AThe upper and lower limits ✓ Correct answer
BThe nominal size and the actual size
CThe GO gauge and the NO-GO gauge
DThe basic size and the deviation
✓ Correct answer: The upper and lower limits
Full explanation
Tolerance is the permitted variation in a dimension: the maximum (upper) limit minus the minimum (lower) limit. It is always positive and is set by the designer; the actual size of a good part must lie between the two limits. It is the same idea as the permissible error in a measurement. The correct answer is The upper and lower limits.
APass through (or over) the part being checked ✓ Correct answer
BNot enter the part being checked
CBe heavier than the part
DBe made of the same metal as the part
✓ Correct answer: Pass through (or over) the part being checked
Full explanation
A GO gauge checks the maximum-material limit - the limit that still allows the parts to assemble - so it must go (pass through a hole, or over a shaft). A NO-GO gauge checks the opposite limit and must not go. If the GO gauge will not enter, the part is too tight; if the NO-GO gauge enters, the part is too loose. The correct answer is Pass through (or over) the part being checked.
Which instrument is used to measure angles precisely in a workshop?
ASine bar ✓ Correct answer
BSlip gauge
CSurface plate
DV-block
✓ Correct answer: Sine bar
Full explanation
A sine bar measures angles precisely: it is set on slip gauges to a known height, and the angle follows from sin(theta) = height / length of the bar. Slip gauges on their own measure length, a surface plate is the flat datum everything is measured from, and a V-block holds round work for marking or drilling.
Ra is the arithmetic average of the roughness profile, and it is quoted in micrometres (microns): a ground surface is typically about 0.4 to 1.6 micrometres Ra, a turned surface rougher. It is a length, not a speed, an angle or a force.
What is the least count of a standard dial indicator?
A0.01 mm ✓ Correct answer
B0.1 mm
C0.001 mm
D1 mm
✓ Correct answer: 0.01 mm
Full explanation
A standard dial indicator reads to 0.01 mm, the same as a micrometer. It is used to check run-out, alignment, parallelism and small variations in size - the needle shows how far the plunger moves from the set zero. A vernier caliper reads to 0.02 mm and a steel rule only to 0.5 mm.