BA transformer with a single winding tapped at different points. ✓ Correct answer
CA transformer that works on DC only.
DA transformer with no iron core.
✓ Correct answer: A transformer with a single winding tapped at different points.
Full explanation
An auto-transformer uses one continuous winding, with part of it common to primary and secondary. It is a transformer with a single winding tapped at different points.
According to Faraday's law of electromagnetic induction, an EMF is induced in a conductor when it:
ACarries a steady direct current in a fixed magnetic field
BCuts across magnetic flux, or the flux linking it changes ✓ Correct answer
CIs placed in a uniform magnetic field and left still
DIs heated above the Curie temperature
✓ Correct answer: Cuts across magnetic flux, or the flux linking it changes
Full explanation
Faraday's law states that an EMF is induced whenever the magnetic flux linking a circuit changes — a conductor cutting flux, or a changing flux through a coil. This induced EMF is the working principle of every generator and transformer. (Pareeksha AEE Electrical — DC and AC Machines; Theraja, Electrical Technology.). The correct answer is Cuts across magnetic flux, or the flux linking it changes.
Why is the core of a transformer and of an AC machine built up of thin laminated sheets instead of one solid iron block?
ATo increase the hysteresis loss
BTo reduce the eddy-current loss ✓ Correct answer
CTo increase the copper loss
DTo reduce the friction loss
✓ Correct answer: To reduce the eddy-current loss
Full explanation
A changing flux induces circulating eddy currents in a solid core, wasting power as heat. Thin laminations insulated from each other break up the eddy-current paths, so the eddy-current loss falls sharply. Hysteresis loss is reduced instead by using good magnetic steel. (Theraja, Electrical Technology; Electronics Hub — transformer tests.). The correct answer is To reduce the eddy-current loss.
The open-circuit (no-load) test on a transformer is performed to find which loss?
AThe copper loss at full load
BThe iron (core) loss ✓ Correct answer
CThe friction and windage loss
DThe stray load loss
✓ Correct answer: The iron (core) loss
Full explanation
In the open-circuit test the secondary is open and rated voltage is applied, so normal flux is set up in the core while almost no load current flows; the wattmeter therefore reads the iron (core) loss — hysteresis plus eddy-current loss — and the no-load current is only 2–5% of rated current. (Electronics Hub — Open Circuit and Short Circuit Test on Transformer; CareerCraftLabs GATE EE Machines.)
The short-circuit test on a transformer is performed to find which loss?
AThe iron (core) loss at rated voltage
BThe copper loss at rated current ✓ Correct answer
CThe dielectric loss of the oil
DThe friction loss of the cooling fans
✓ Correct answer: The copper loss at rated current
Full explanation
In the short-circuit test the secondary is shorted and only a small voltage (about 5–10% of rated) is applied — just enough to circulate rated current. Core loss is negligible at that low voltage, so the wattmeter reads the full-load copper (I²R) loss, and the test also gives the series leakage impedance. (Electronics Hub — Open Circuit and Short Circuit Test on Transformer; CareerCraftLabs GATE EE Machines.). The correct answer is The copper loss at rated current.
What is meant by the voltage regulation of a transformer?
AThe ratio of primary voltage to secondary voltage at no load
BThe percentage rise in secondary terminal voltage from full load to no load, at constant primary voltage ✓ Correct answer
CThe percentage fall in frequency from no load to full load
DThe ratio of output power to input power
✓ Correct answer: The percentage rise in secondary terminal voltage from full load to no load, at constant primary voltage
Full explanation
Voltage regulation is the change in secondary terminal voltage when the load is removed, expressed as a percentage of the full-load voltage: (V_no-load − V_full-load) / V_full-load × 100. It is caused by the resistance and leakage reactance drops in the windings, and it can be negative for a leading (capacitive) load. (CareerCraftLabs GATE EE Machines; ECExplain transformer interview questions.). The correct answer is The percentage rise in secondary terminal voltage from full load to no load, at constant primary voltage.
What is the all-day efficiency of a distribution transformer?
AThe efficiency measured at full load only
BThe ratio of the energy delivered in 24 hours to the energy supplied in 24 hours ✓ Correct answer
CThe efficiency at the maximum-efficiency load point
DThe ratio of output voltage to input voltage over a day
✓ Correct answer: The ratio of the energy delivered in 24 hours to the energy supplied in 24 hours
Full explanation
A distribution transformer stays energised all 24 hours but is loaded only part of the time, so its ordinary (commercial) efficiency at one load does not describe a day's working. All-day efficiency is the energy (kWh) delivered over 24 hours divided by the energy supplied over 24 hours, and it is lower than the maximum efficiency because the iron loss runs all day. (Theraja, Electrical Technology; ECExplain transformer interview questions.). The correct answer is The ratio of the energy delivered in 24 hours to the energy supplied in 24 hours.
In the EMF equation of a DC generator, Eg = PΦNZ / 60A, what does A stand for?
AThe armature current in amperes
BThe number of parallel paths in the armature winding ✓ Correct answer
CThe cross-sectional area of the armature
DThe number of armature slots
✓ Correct answer: The number of parallel paths in the armature winding
Full explanation
In Eg = PΦNZ/60A, P is the number of poles, Φ the flux per pole in webers, N the speed in rpm, Z the total number of armature conductors, and A the number of parallel paths in the armature winding. The generated EMF is proportional to flux and speed (Eg ∝ ΦN). (Pareeksha AEE Electrical — DC Machines; ISBM Library, DC Machines and Control.)
In a DC machine, how many parallel paths (A) does a simplex lap winding have, and how many does a simplex wave winding have?
ALap: A = 2; wave: A = P (number of poles)
BLap: A = P (number of poles); wave: A = 2 ✓ Correct answer
CLap: A = P; wave: A = P
DLap: A = 2; wave: A = 2
✓ Correct answer: Lap: A = P (number of poles); wave: A = 2
Full explanation
For a simplex lap winding the number of parallel paths equals the number of poles (A = P), so it suits low-voltage, high-current machines; for a simplex wave winding there are always two parallel paths (A = 2) whatever the pole count, so it suits high-voltage, low-current machines. (Pareeksha AEE Electrical — DC Machines; ISBM Library, DC Machines and Control.). The correct answer is Lap: A = P (number of poles); wave: A = 2.
Why must a large DC motor be started through a starter instead of being switched directly onto the supply?
ABecause the field winding would burn out at full voltage
BBecause at standstill the back EMF is zero, so the starting current would be dangerously high ✓ Correct answer
CBecause the commutator cannot work at full speed
DBecause the motor would run backwards without a starter
✓ Correct answer: Because at standstill the back EMF is zero, so the starting current would be dangerously high
Full explanation
At standstill the speed is zero, so the back EMF Eb is zero and the armature current would be V/Ra. Since Ra is very small (often below 1 ohm), this current can be 10–20 times the rated value, damaging the commutator and windings. A starter inserts resistance that is cut out step by step as the motor speeds up and the back EMF builds. (Pareeksha AEE Electrical — DC Machines; ISBM Library, DC Machines and Control.). The correct answer is Because at standstill the back EMF is zero, so the starting current would be dangerously high.
Which method of speed control gives a DC shunt motor speeds ABOVE its normal (base) speed?
AArmature resistance control
BField (flux) control — weakening the field with a rheostat in the field circuit ✓ Correct answer
CReducing the supply voltage
DIncreasing the load on the motor
✓ Correct answer: Field (flux) control — weakening the field with a rheostat in the field circuit
Full explanation
Speed N is proportional to Eb/Φ, so weakening the field flux Φ raises the speed — field control gives speeds above base speed. Armature resistance control and reducing the armature voltage give speeds below base speed only, and increasing the load lowers the speed slightly. (Pareeksha AEE Electrical — DC Machines; PYQGate GATE EE, DC Machines.). The correct answer is Field (flux) control — weakening the field with a rheostat in the field circuit.
What is the synchronous speed of an 8-pole induction motor on a 50 Hz supply?
A1500 rpm
B1000 rpm
C750 rpm ✓ Correct answer
D3000 rpm
✓ Correct answer: 750 rpm
Full explanation
Synchronous speed Ns = 120f/P = 120 × 50 / 8 = 750 rpm. The rotor of an induction motor always runs slightly slower than this, the difference being the slip. (Pareeksha AEE Electrical — Three-phase induction motors; Electrical Workbook — slip in induction motor.)
A 4-pole, 50 Hz induction motor runs with a slip of 4%. What is the frequency of the rotor currents?
A50 Hz
B25 Hz
C4 Hz
D2 Hz ✓ Correct answer
✓ Correct answer: 2 Hz
Full explanation
Rotor frequency fr = s × f, where s is the slip and f the supply frequency: fr = 0.04 × 50 = 2 Hz. At standstill s = 1 and the rotor frequency equals the supply frequency; at synchronous speed s = 0 and no EMF is induced in the rotor. (Pareeksha AEE Electrical — Induction Motors; Electrical Workbook — slip in induction motor.)
Compared with direct-on-line starting, a star-delta starter reduces the starting current of a squirrel-cage induction motor to about:
AOne-half of the direct-on-line value
BOne-third of the direct-on-line value ✓ Correct answer
COne-sixth of the direct-on-line value
DThe same value — it only reduces the starting torque
✓ Correct answer: One-third of the direct-on-line value
Full explanation
In star the voltage across each winding is 1/√3 (about 58%) of the line voltage, so the starting current — and the starting torque — fall to about one-third of the direct-on-line values. The motor starts in star and is switched to delta once it is running. (AskFilo — star-delta starter; Pareeksha AEE Electrical — Induction Motors.)
Which type of induction-motor rotor lets the starting torque be raised and the speed controlled by adding external resistance in the rotor circuit?
AThe squirrel-cage rotor
BThe slip-ring (wound) rotor ✓ Correct answer
CThe solid steel rotor
DThe permanent-magnet rotor
✓ Correct answer: The slip-ring (wound) rotor
Full explanation
A slip-ring (wound) rotor brings its winding out through slip rings, so external resistance can be added: it raises the starting torque and allows speed control, which is why slip-ring motors are used for cranes, hoists and mills. A squirrel-cage rotor is simpler and cheaper but its rotor resistance is fixed, so its starting torque is low and cannot be adjusted. (Pareeksha AEE Electrical — Induction Motors; Theraja, Electrical Technology.). The correct answer is The slip-ring (wound) rotor.
On the V-curve of a synchronous motor at constant load, what power factor does the motor have when it is over-excited?
ALagging power factor
BUnity power factor
CLeading power factor ✓ Correct answer
DZero power factor
✓ Correct answer: Leading power factor
Full explanation
A V-curve plots armature current against field current at constant load. At normal excitation the current is minimum and the power factor is unity; under-excited the motor draws lagging current, and over-excited it draws leading current — it then supplies reactive power to the system like a capacitor. (IIT Kharagpur, V-curves of a synchronous machine; Elec-Buddy — synchronous motor.). The correct answer is Leading power factor.
AA capacitor bank connected across a synchronous motor
BAn over-excited synchronous motor running on no load, used to improve the power factor ✓ Correct answer
CA condenser that cools the windings of an alternator
DAn under-excited synchronous motor used as a generator
✓ Correct answer: An over-excited synchronous motor running on no load, used to improve the power factor
Full explanation
When an over-excited synchronous motor runs on no load, it draws an almost purely leading current — it behaves exactly like a capacitor. It is then called a synchronous condenser (or synchronous capacitor) and is used as a phase advancer to correct the power factor of a plant. (Poriyaan two-marks Q&A — Synchronous Motor; Elec-Buddy — synchronous motor.). The correct answer is An over-excited synchronous motor running on no load, used to improve the power factor.
What is hunting in a synchronous motor, and what damps it?
AHunting is overheating of the field winding; it is damped by cooling fans
BHunting is the periodic swinging of the rotor about its new load angle after a sudden load change; the damper (amortisseur) winding damps it ✓ Correct answer
CHunting is the search for synchronous speed at start; it is damped by the starter resistance
DHunting is vibration of the bearings; it is damped by lubrication
✓ Correct answer: Hunting is the periodic swinging of the rotor about its new load angle after a sudden load change; the damper (amortisseur) winding damps it
Full explanation
When the load changes suddenly the rotor, because of its inertia, overshoots its new equilibrium load angle and swings back and forth about it — this periodic swinging is hunting. Currents induced in the damper (amortisseur) winding in the pole faces produce a torque that opposes the swing until it dies away. The same winding also lets the motor start as an induction motor. (Elec-Buddy — synchronous motor; Poriyaan two-marks Q&A — Synchronous Motor.). The correct answer is Hunting is the periodic swinging of the rotor about its new load angle after a sudden load change; the damper (amortisseur) winding damps it.