What is a main benefit of negative feedback in a control system?
AIt increases sensitivity to disturbances.
BIt reduces sensitivity to disturbances and parameter changes. ✓ Correct answer
CIt makes the system unstable.
DIt removes the need for a controller.
✓ Correct answer: It reduces sensitivity to disturbances and parameter changes.
Full explanation
Negative feedback corrects errors as they appear, so the output stays close to the desired value. It reduces sensitivity to disturbances and parameter changes.
BThe ratio of the Laplace transform of the output to that of the input. ✓ Correct answer
CThe gain of the amplifier.
DThe frequency of oscillation.
✓ Correct answer: The ratio of the Laplace transform of the output to that of the input.
Full explanation
A transfer function describes a linear system in the s-domain with zero initial conditions. It is the ratio of the Laplace transform of the output to that of the input.
For a linear control system to be stable, where must all the poles of its transfer function lie?
AOn the imaginary axis.
BIn the right-half of the s-plane.
CIn the left-half of the s-plane. ✓ Correct answer
DAt the origin.
✓ Correct answer: In the left-half of the s-plane.
Full explanation
Poles in the left-half plane give decaying responses, while poles in the right-half plane grow without bound. For stability, all poles must lie in the left-half of the s-plane.
AProportional integral derivative. ✓ Correct answer
BPower input device.
CPhase inverter driver.
DPulse interval detector.
✓ Correct answer: Proportional integral derivative.
Full explanation
A PID controller combines three actions: one based on the present error, one on past error, and one on the rate of change of error. PID stands for proportional integral derivative.
BThe difference between the desired and actual output after the response settles. ✓ Correct answer
CThe maximum overshoot.
DThe time to reach the peak.
✓ Correct answer: The difference between the desired and actual output after the response settles.
Full explanation
After the transient dies away, a system may still sit slightly away from the target value. Steady-state error is the difference between the desired and actual output after the response settles.
BThe magnitude and phase of a system against frequency. ✓ Correct answer
CThe location of poles and zeros.
DThe step response only.
✓ Correct answer: The magnitude and phase of a system against frequency.
Full explanation
A Bode plot has two graphs: gain in decibels and phase in degrees, both plotted against frequency. It shows the magnitude and phase of a system against frequency.
What is the time constant of a first-order system?
AThe time to reach 63.2 percent of the final value. ✓ Correct answer
BThe time to reach 100 percent of the final value.
CThe time to reach the peak.
DThe time to settle within 2 percent.
✓ Correct answer: The time to reach 63.2 percent of the final value.
Full explanation
For a first-order step response, the output reaches about 63.2 percent of its final value in one time constant. The time constant is the time to reach 63.2 percent of the final value.
BTo test the stability of a system from its characteristic equation. ✓ Correct answer
CTo draw the Bode plot.
DTo design a PID controller.
✓ Correct answer: To test the stability of a system from its characteristic equation.
Full explanation
The Routh-Hurwitz method checks whether any roots of the characteristic equation lie in the right-half plane, without solving it. It is used to test the stability of a system from its characteristic equation.
BThe stability of a closed-loop system from its open-loop frequency response. ✓ Correct answer
CThe rise time.
DThe damping ratio.
✓ Correct answer: The stability of a closed-loop system from its open-loop frequency response.
Full explanation
The Nyquist plot of the open-loop response tells whether the closed loop will be stable. It determines the stability of a closed-loop system from its open-loop frequency response.
BHow much gain or phase lag a stable system can tolerate before becoming unstable. ✓ Correct answer
CThe steady-state error.
DThe overshoot.
✓ Correct answer: How much gain or phase lag a stable system can tolerate before becoming unstable.
Full explanation
Gain and phase margins show how close a stable system is to instability. They measure how much gain or phase lag a stable system can tolerate before becoming unstable.
What is the main difference between feedforward and feedback control?
AFeedforward measures the output.
BFeedforward acts on the disturbance before it affects the output. ✓ Correct answer
CFeedforward needs no model.
DFeedback acts before the disturbance.
✓ Correct answer: Feedforward acts on the disturbance before it affects the output.
Full explanation
Feedforward uses a model of the disturbance to correct it in advance, while feedback only reacts after an error appears. Feedforward acts on the disturbance before it affects the output.
BTo control machines and processes automatically. ✓ Correct answer
CTo measure voltage.
DTo store data only.
✓ Correct answer: To control machines and processes automatically.
Full explanation
A programmable logic controller runs logic that switches motors, valves and other equipment on and off. It is used to control machines and processes automatically.