The bulk density of aggregates does not depend upon:
ASize and shape of aggregates
BSpecific gravity of aggregates
CGrading of aggregates
DSize and shape of the container ✓ Correct answer
✓ Correct answer: Size and shape of the container
Full explanation
Bulk density depends on the size, shape, grading and specific gravity of the aggregates, but not on the Size and shape of the container they are measured in.
Curing keeps concrete moist so it gains strength, and it reduces shrinkage, preserves its properties and prevents loss of water by evaporation, so All of these is correct.
The shape and grading of the particles and how well they are compacted all change the voids, so the bulk density of aggregates depends on All of these.
CPressure compaction of the bags on lower layers ✓ Correct answer
DPacking the warehouse
✓ Correct answer: Pressure compaction of the bags on lower layers
Full explanation
Cement bags stored in a warehouse get pressed together under their own weight, so 'warehouse pack' means Pressure compaction of the bags on lower layers.
The effective length of a rafter member between two nodes at a distance L, perpendicular to the plane of the truss, is:
A2.00 L
B0.85 L ✓ Correct answer
C1.50 L
D1.00 L
✓ Correct answer: 0.85 L
Full explanation
For a compression member such as a rafter, the effective length is taken as 0.85 L, because the restraint at the nodes reduces it below the full node-to-node distance L.
A doubly reinforced concrete beam has effective cover d' to the centre of compression reinforcement. xu is the depth of the neutral axis, and d is the effective depth to the centre of tension reinforcement. What is the maximum strain in concrete at the level of compression reinforcement?
A0.0035 (1 - d'/d)
B0.0035 (1 - d'/xu) ✓ Correct answer
C0.002 (1 - d'/xu)
D0.002 (1 - d'/d)
✓ Correct answer: 0.0035 (1 - d'/xu)
Full explanation
Strain varies linearly from 0.0035 at the extreme compression fibre, so at a depth d' below it the strain is 0.0035 (1 - d'/xu), where xu is the neutral axis depth.
AThe cross-sectional area of longitudinal reinforcement should not be less than 0.8% nor more than 4% of the gross sectional area
BThe minimum numbers of longitudinal bars provided in rectangular and circular columns are 4 and 6 respectively
CIn a helical reinforced column, the minimum number of longitudinal bars should be six
DAll of these ✓ Correct answer
✓ Correct answer: All of these
Full explanation
The 0.8% to 4% steel limits, the minimum of 4 bars in a rectangular column and 6 in a circular one, and 6 bars minimum in a helical column are all code requirements, so All of these is correct.
If an element of a stressed body is in a state of pure shear with a magnitude of 80 N/mm2, the magnitude of the maximum principal stress at that location is:
A80 N/mm2 ✓ Correct answer
B113.14 N/mm2
C120 N/mm2
D56.57 N/mm2
✓ Correct answer: 80 N/mm2
Full explanation
In pure shear the principal stresses are equal in magnitude to the shear stress, so the maximum principal stress is 80 N/mm2.